    Pretty sure most modern data centers are using closed loop cooling or refrigeration. Not evaporative cooling.

    You can’t condense the water either that would defeat the point of evaporating it in the first place. Closed loop liquid cooling does not involve boiling or evaporation. You are just pumping a liquid around a circuit. It’s not just water either it’s more like a car antifreeze.

    • KnitWit@lemmy.world
      link
      fedilink
      English
      arrow-up
      3
      arrow-down
      2
      ·
      edit-2
      18 hours ago

      Got any info to back that up? Here’s a screenshot from page 39 of the US Data Center Energy Usage Report, which shows the use of closed loop systems (which they call dry cooling) as one of the smallest percentages of cooling types used. Pretty sure you’ve got it completely backwards on the types of cooling used, and I know for a fact the massive Amazon data center out in Oregon uses evaporative, because you can’t drink the water there as a result.

      • Buddahriffic@lemmy.world
        link
        fedilink
        English
        arrow-up
        2
        ·
        18 hours ago

        The laws of thermodynamics? Can’t create or destroy energy and overall entropy increases over time. A closed loop (or any cooling system) just moves heat away from the hot thing. So yes, they can be used as much as any other cooling system but it won’t stop the issue of “generating lots of heat”. That heat still needs to go somewhere. Dumping it into the atmosphere might be the best option if there’s nothing in the area that needs heat. Should probably build them next to steel plants or something like that. Then a closed loop would be better.

        • NotANumber@lemmy.dbzer0.com
          link
          fedilink
          English
          arrow-up
          2
          arrow-down
          2
          ·
          17 hours ago

          I never said it fixed the issue of generating heat. Heat isn’t really a major problem as far as I am concerned. I thought we were talking about water use.

        • KnitWit@lemmy.world
          link
          fedilink
          English
          arrow-up
          1
          arrow-down
          2
          ·
          edit-2
          17 hours ago

          ? OP was claiming that the majority of data centers use closed loop/refrigeration systems and I was pointing out that US data shows the vast majority use evaporative cooling. They posted a few comments pushing that idea which is why I refuted that. I’m not sure what the point you’re trying to make is in regards to those two statements. I’m not disputing the accuracy of what you’re saying, just unsure of where you’re going with it.

          • Buddahriffic@lemmy.world
            link
            fedilink
            English
            arrow-up
            2
            ·
            16 hours ago

            Thought your request to back it up was in response to the parent comment saying that condensing the water defeats the purpose rather than the first paragraph.

      • NotANumber@lemmy.dbzer0.com
        link
        fedilink
        English
        arrow-up
        3
        arrow-down
        2
        ·
        17 hours ago

        Why would they call closed loop liquid cooling “dry cooling”? Unless they explicitly said that then I don’t believe you to be honest.

        Evaporative cooling wouldn’t make the water undrinkable unless something has gone very wrong. So I don’t think what you are saying about Oregan is true either.

        This is also only representative of the USA, not worldwide. I get that much of the world doesn’t have many datacenters compared to the USA, but you at least have to include China and the EU.